ZETTLER RS800-IP/GPRS - IP Communication Module

 
Simplified site for mobile users


  Home > Addressable Products & Systems > RS800-IP/GPRS - IP Communication Module

RS800-IP/GPRS - IP Communication Module

The RS800-IP/GPRS module connects to an individual or a network of MZX, MX, ZX, MX2 and T2000 fire control panels to provide a cost effective, secure and robust IP (Internet Protocol) based communication platform for alarm signalling, fault reporting and a range of remote services.

Features:

  • A cost effective digital communication platform to enable a range of remote services
  • Robust dual path transmission over the clients IT network and the GPRS network, ensures continuity of communication in the event of a failure
  • Regular polling of the IP path and the GPRS path confirms successful end to end communication - a failure will be reported within 3 minutes
  • Secure communication is ensured by AES encryption with a 128 bit key and 256 bit hash code
  • BRE approved to EN 54-21 for fire alarm transmission and fault warning routing equipment and LPCB Red Book listed
  • Supplied with an activated 02 SIM card
  • All access is securely controlled and logged

TrueInsight
To view information on the TrueInsight system, please click on the button below:

 

 

System Description:

The RS800-IP/GPRS module connects to the communication ports and relays of a fire control panel and converts the RS232 and digital data into IP data that can be transmitted over the internet.

Communication is dual path. The primary path is the clients IP network, eliminating the additional cost of a traditional PSTN telephone line. Efficient, digital communication puts negligible demand on the network and ensures future compatibility as the traditional analogue systems are progressively phased out.

The GPRS mobile communication network is the secondary path and maintains communication in the event of a failure of the primary path.

All communication to and from a fire control panel is managed by the monitoring centre transceivers - dedicated servers. The primary IP path is polled (checked) every 30 seconds and the secondary GPRS path every 60 seconds to confirm successful end to end communication. A failure in either path will be reported within 3 minutes.

Secure communication is ensured by AES encryption with a 128 bit key and 256 bit hash code. Message and device substitution protection provides security against external attacks.

Minimal demand is placed on the communications network with low level normal data transfer of only 160 bytes every 30 seconds.

The security of the client's IP network is not compromised as all communication is initiated outbound by the RS800-IP/GPRS. If required, fixed routing / port mapping is available.

The panel software MZX Consys Version 19 onwards, has been developed to optimise data transfer and also to incorporate the recommendations of the Euralarm Technical Group on "Remote Services for Alarms".

For more information on the TrueInsight Fire Detection Monitoring System, please click here
 

  
     

Information Available:

Approval Certificates
Doc. No. Description
Language
008/BM-PSYS/009/5 115309 WÄRMEMELDER / 150971 STREULICHTSENSOR / 168242 WARMEMELDER / 180029 STAB - WÕRMEMELDER 60 G / 180030 STAB-WÕRMEMELDER 70 GRA / 2WIRE OPTICAL SMOKE DETECTOR / 4B DETECTOR BASE / 4B-C CONTINUITY BASE / 4B-I ISOLATOR BASE / 5B 5" UNIVERSAL BASE / 5BEX 5" UNIVERSAL EX BASE / 5BI 5" ISOLATOR BASE / 601F CONVENTIONAL FLAME DETECTOR / 601FEX CONVENTIONAL I.S. FLAME DETECTOR / 601H-F CONVENTIONAL FIXED TEMPERATURE DETECTOR / 601H-R CONVENTIONAL RATE OF RISE DETECTOR / 601P CONVENTIONAL PHOTO OPTICAL SMOKE DETECTOR / 601PH HIGH PERFORMANCE PHOTO OPTICAL SMOKE DETECTOR / 8 WAY INPUT-OUTPUT PCB / 801CHEX I.S. CO + HEAT DETECTOR / 801F MX FLAME DETECTOR / 801FEX MX I.S. FLAME DETECTOR / 801H MX HEAT DETECTOR / 801HEX I.S. HEAT DETECTOR / 801IB MX ISOLATOR BASE / 801PH MX PHOTO OPTICAL + HEAT DETECTOR / 801PHEX I.S. PHOTO OPTICAL + HEAT DETECTOR / 802SB MX LOW POWER SOUNDER BASE / 802SB ZX SOUNDER BASE / 813P MX PHOTO OPTICAL DETECTOR / 830H HEAT DETECTOR / 830P PHOTO OPTICAL DETECTOR / 830PC 3OTEC TRIPLE SENSOR DETECTOR / 830PH PHOTO OPTICAL HEAT DETECTOR / 850H HEAT DETECTOR / 850P PHOTO OPTICAL DETECTOR / 850PC 3OTEC TRIPLE SENSOR DETECTOR / 850PH PHOTO OPTICAL HEAT DETECTOR / A14 150970 IONISATIONSSENSOR / A720 & A823 FEUERMELDER / A9 115301 I-RAUCHMELDER / ANN840 40 WAY ALARM-FAULT ISOLATOR LED MODULE / ANN880 80 WAY ALARM LED MODULE / AZT FILNET - INDICATOR PANEL / BACNET CONVERTER FOR MZX / BAQ140T24 5.0A PSU / BDM800 BEAM DETECTOR MODULE / BTM800 BEAM TERMINAL MODULE / CCU3/485/TNMB1 TNET/MODBUS / COM820 20 WAY STATUS-COMMAND MODULE / CPU800 1MB CPU PCB / CS-EX1.54 GALVANIC ISOLATOR / DCM832 32 ZONE DISPLAY BOARD / DIM800 DETECTOR INPUT MODULE / DIN820 CALLPOINT / DIN830 CALLPOINT / EXC EXT CONVENTIONAL BOARD / EXI800 MX I.S. LOOP INTERFACE / FB800 MX 15 WAY FUSE BOARD / FIM801 MX FIELD INTERFACE MODULE 1 LOOP / FIM802 MX FIELD INTERFACE MODULE 2 LOOP / FIRERAY 100R DETECTOR / FIRERAY 5000 SYSTEM / FIRERAY 50R DETECTOR / FM50KU DRUCKKNOPFMELDER FÜR INNNEN / FM60 DRUCKKNOPF-FEUERMELDER / FOM800 FIBRE OPTIC MODULE / FV311S 20MM FLAME DETECTOR / FV311SC 20MM PAL FLAME DETECTOR / FV311SCN 20MM NTSC FLAME DETECTOR / FV312S F-L FLAME DETECTOR / FV312SC F-L PAL FLAME DETECTOR / FV312SCN F-L NTSC FLAME DETECTOR / HM3-D1 205812 HANDFEUERMELDER HM3-D1 / ILA ZETFAS ADD INDICATOR / IOB800 STD 8 INPUT-8 OUTPUT EXPANSION BOARD / IOM INPUT-OUTPUT MONITORED MODULE / IOUM INPUT-OUTPUT UNMONITORED MODULE / IS-SHUNT ZENER DIODE BARRIER / LIM800 SHORT CIRCUIT ISOLATOR MODULE / LPAV3000 LP SOUNDER-BEACON BASE / LPAV800-R SOUNDER / LPAV800-W SOUNDER / LPAV865 SOUNDER / LPSB3000 LP SOUNDER BASE / LPSY800-R SOUNDER / LPSY800-W SOUNDER / LPSY865 SOUNDER / M1 213567 IONISATIONSMELDER / M613 DETECTOR BASE / MD601EX CONVENTIONAL ROR HEAT I.S. DETECTOR / MDU601EX CONVENTIONAL COMBINED I.S. HEAT + CO DETECTOR / MIL 16 WAY OUTPUT UNIT / MPM800 MULTI-PURPOSE INTERFACE MODULE / MR601TEX CONVENTIONAL HPO I.S. DETECTOR / MT BANSHEE RED LP SOUNDER BASE / MZX-16-R 16 ZONE AC REPEATER / MZX-251 32 ZONE 1 LOOP PANEL / MZX-252 32 ZONE 2 LOOP PANEL / MZX-254 2 LOOP 240 ZONE PANEL / MZX-32-R 32 ZONE AC REPEATER / MZX-64DR 64 ZONE DC REPEATER / MZX-DR 240 ZONE DC REPEATER / OCM800 MODULE / ODM800 OPERATOR DISPLAY MODULE / OR3-M1 OPTICAL DETECTOR / PSM800 STANDARD PSU MODULE / PSU A38 - 5A EXPANSION PSU / PSU830 POWER SUPPLY MODULE / QIO850 QUAD INPUT-OUTPUT MODULE / QMO850 QUAD MONITORED OUTPUT MODULE / QRM850 QUAD RELAY MODULE / RS800 WEBWAY IP - GPRS INTERFACE / S1 223498 MULTISENSOR OW3-S1 / S1 ZETFAS HEAT DETECTOR / S1 ZETFAS IONISATION DETECTOR / S1 ZETFAS OPTICAL DETECTOR / S271I+ MX TRIPLE IR FLAME DETECTOR / SAM800 ZX SOUNDER ADD MODULE / SMP69 DUCT PROBE UNIT / SPF600 I.S. DETECTOR BASE / TLI800EN NETWORK CARD / TUD800 GERMAN TRANS UNIT / VLC-800-MX LASER COMPACT / VLF-250-01 LASFOCUS EUR DECAL / VLP-012 VLP-012 RAUCHMELDER / VLS-214 SCAN+RAUCH / VLS-700 VLC-500RO KOMPACT / W3-M1 WÕRMEMELDER / XCC-010 ASPIRATING DETECTOR / XLM ZETFAS LOOP CARD / XLM800 MX LOOP EXPANSION MODULE / ZETFAS ZMU / ZX UNIVERSAL BOX / ZX1 1 LOOP PANEL / ZX4 2-4 LOOP PANEL / ZX4-BB BLACK BOX PANEL / ZXAEV-17 5A PSU / ZXAEV-38 5A PSU / ZXF FULL REPEATER / ZXFEV REPEATER / ZXFEV-UP REPEATER - VB (14.67M) Added:31/05/2017
 ENG
0832-CPD-1565 WEBWAY IP/GPRS LPS FIRE TYPE 1 - BRE EC CERTIFICATE OF CONFORMITY (212k) Added:26/10/2011
 ENG
1022a/01 RS800 WebWay IP/ GPRS Interface - BRE/LPCB (651k) Added:11/11/2011
 ENG
Brochures & Datasheets
Certificates of Conformity & Performance
Declarations of Conformity & Performance
  
   There are no documents of this type available
  
Green Passport
  
   There are no documents of this type available
  
  
  
     

ABOUT US
Johnson Controls is dedicated to advancing fire safety and security by finding innovative ways to save lives, improve businesses and protect people where they live and work.
  

 

Useful Links
Johnson Controls

© 2018 Johnson Controls. All rights reserved.

Privacy Policy / Terms of Sale / Cookies / Modern Slavery Act / Contact